Troubleshooting

Here are some commonly asked troubleshooting questions we get from our new spa owners. If you do not see your question here please do not hesitate to contact one of our friendly specialists.

This thing is so cool! But it doesn't seem to be reaching my desired temperature or I think it's losing heat?

First, please remember there are two things to consider when first heating your spa. The temperature of the ambient air as well as the initial temperature of the water. During the first heating your spa will rise in temperature by 1 to 1 1/2 degrees every hour. If you wish to speed up the process you can always supplement hot water into your spa.

snbredwfireplc.jpg

Also your spa will not register initial heat reading on your thermostat till it reaches 66F.

Still not heating after 36 hours?

1. With GFCI plugged into wall outlet, Is topside LED displaying any Temperature Number?  If NO, go to GFCI problems. If Yes go to next step.

2. Place your hand in front of lower water return inlet inside your hot tub to see if there is good water flow. Do you feel good water flow? If NO, go to Low/No water flow, pump rattling section. If Yes, go to next step.

3. Place index finger over lower water return inlet hole and stop flow. Hold for 15 seconds, then pull finger back apx. 1/2" and see if you feel a quick short pulse of warm water. If Yes, spa is now heating. This may have reset a pressure switch, but this usually indicates a dirty filter/ low flow condition. If No, go to next step.

4. Some Power Pack units have a high limit reset button located under the pack about 2 inches inward from right leg.  Unplug power pack! Push this button.  If you feel a click,plug power pack into outlet, reset desired water temperature and repeat step 3. If you feel a pulse of warm water, spa is heating. If NO, go to next step.

5. If all above fails to create a short pulse of warm water after stopping flow with finger, there may be a problem with heater element, pressure switch, high limit switch or electronic control. The power pack may need to be sent to service center for repairs. General Notes: Most no heat issues are almost always the result of a dirty filter/low flowa tripped high limit button under pack, or the pump/filter tank was not properly bled of air, resulting in a rattling pump noise and the pump not flowing ANY water. Remember if the pump is not flowing a good stream of water the spa will not heat.

 

I think I'm having an issue with my GFCI?

WARNING ! The GFCI (Ground Fault Circuit Interrupter) is a safety device. This will prevent SHOCK or ELECTROCUTION, but will only offer protection when plugged into a "PROPERLY GROUNDED 3 PIN WALL RECEPTACLE!

If the GFCI is plugged into an ungrounded Outlet, or extension cord, THERE IS NO SHOCK PROTECTION.

HAVE A QUALIFIED LICENSED ELECTRICIAN VERIFY WALL OUTLET / RECEPTACLE IS PROPERLY GROUNDED! DO NOT BYPASS GFCI WITH STANDARD PLUG and DO NOT USE EXTENTION CORDS.
 
1. Make sure GFCI is plugged into a properly grounded 3 pin wall receptacle, NO EXTENSION CORDS. Is there power to Power Pack / Does LED temp display show any temperature? If NO, plug lamp or hair dryer into outlet to see if there is power to outlet. If no power, call an electrician or check breaker. If the temperature display shows temp. go to next step. 
 
2. Does GFCI trip / shut off after a couple of seconds when first plugged in or reset in heat / circulation mode? If YES, GFCI may be working properly and sensing a short to ground in heater circuit, heater element or electric terminal in Power Pack has become wet. DO NOT USE! Power Pack should be sent to Service Center for inspection / repair. If NO, go to next step. 
 
3. Does GFCI trip / shut off when Blower / Turbo button is pressed? If Yes, Blower may have become wet. Remove Blower Loop and look down left hand pipe. If water is standing in the bottom of left hand pipe when Power Pack is attached to spa full of water, unplug and do not use spa. Air check valve has failed and needs to be replaced, send to service center for repair. If no water is present in left hand pipe, unplug unit, place hair dryer or shop vac in right hand pipe hole and run for 10 minutes. This will dry Blower motor if it has moisture on it. After 10 minutes, plug Power Pack into wall outlet and press Blower / Turbo button. If Blower runs, let it run for it's 15 - 20 minute cycle. This will help continue to dry it out. Replace Blower Loop. 
 
4. Test GFCI before each use. Press Test button as it should trip, the press Reset button. If it does not trip or reset, DO NOT USE SPA! It is either plugged into an ungrounded outlet or it is doing it's job and sensing a short to ground, or may be defective and needs to be replaced. Power Pack needs to be sent to service center for repair. DO NOT BYPASS OR REPLACE GFCI WITH STANDARD PLUG. THIS WILL BYPASS SHOCK PROTECTION.

 

 

I think I'm having low flow water problem?couple-oneside.jpg

 1. Make sure 3 fitting caps have been removed from inside spa suction & return flow fittings. These are only used when cleaning filter, to keep water from overflowing filter tank when lid is removed.

2. Bleed air from filter tank. To do this make sure Power Pack is unplugged from outlet. Open air valve on top of filter tank until water spews from valve. Close air valve, plug GFCI back into outlet. Verify there is good water flow by placing hand in front of lower water return inlet and feeling good water flow.

3. Clean or replace filter cartridge. As the filter begins to get dirty, the flow of water slows down as the pump has a difficult time drawing the water through the dirt impregnated filter. This is the most common cause of a spa not heating. The spa can not heat without good water flow. 

4. Pump impeller clogged with debris. Please first unplug Power Pack, place caps over fittings in tub. Remove filter and drain filter tank. Look down in the center hole on the bottom of the filter tank and you will see the paddle wheel impeller from the pump. This is a magnetic drive circulating pump and it does not take much of a debris clog to keep it from spinning.Take a long, thin screw driver and place in the hole and try to turn it a few times. Remove screw driver and plug power pack in for a few seconds. If it spins freely on it's own, it should now pump water. Unplug unit, bleed air, plug back into wall receptacle and verify water flow with hand.

 

 

My jets don't seem to be working? 

1. Does Turbo / Air Blower turn on. If NO, check unit plugged in / Temperature display illuminated. If Air Blower does not turn on, go to GFCI trouble shooting section. If Blower turns on go to next step.

2. If Blower turns on for a second, then trips GFCI, go to GFCI troubles shooting section. Blower may be wet.

3. If Blower turns on, but does not blow air all the way around the bubble ring in spa, or shuts off by itself after a minute or two, check union O-ring tape has been removed during initial installation. Two pieces of criss-crossed tape are placed over the lower union connection from the factory. This is used to keep the union o-ring in place and not falling out during shipping. If BOTH pieces are not removed, the air check valve will not be allowed to fully open. The result will be little or  no air flow into the bubble ring in spa, and will also result in the blower overheating. Remove tape and allow blower to cool for 1 hour & retry.
Be careful to keep union O-ring in it's groove or spa will leak at that connection.

4. If it is verified blower motor is dry in GFCI troubleshooting, and GFCI trips when Turbo/ Air Blower button is pushed, the blower motor may need to be replaced. Send Power Pack to service center for repair.

5. If Blower runs and above steps have been checked with spa drained, disconnect Blower Union nut from Power Pack and pull pack away from spa a few inches. Turn blower on and see if air flows from check valve fitting ( Large lower connection on Power Pack. A 1/4" round peg should pop out of center of check valve and you should feel air flow when you put you hand in front of fitting. If not, check valve could be stuck in closed position, or check valve spring rusted shut. Replace check valve or send Power Pack into service center for repair.

 

If you find your question has not been answered here, please do not hesitate to contact our Specialists at 888-997-6366 or email us at info@comfortlineproducts.com.

 